Your browser version may not work well with NCBI's Web applications. More information here...

Recent Activity

Items 1 - 20 of 114
of 6Next
1:

Influence on fluid dynamics of coronary artery outlet angle variation in artificial aortic root prosthesis.

Verhey JF, Bara C.

Biomed Eng Online. 2008 Feb 28;7:9.

PMID: 18307786 [PubMed - indexed for MEDLINE]

2:

Simulation of the fluid dynamics in artificial aortic roots: comparison of two different types of prostheses.

Bara CL, Verhey JF.

J Artif Organs. 2008;11(3):123-9. Epub 2008 Oct 5.

PMID: 18836872 [PubMed - in process]

4:

Computational model of blood flow in the aorto-coronary bypass graft.

Sankaranarayanan M, Chua LP, Ghista DN, Tan YS.

Biomed Eng Online. 2005 Mar 4;4(1):14.

PMID: 15745458 [PubMed - indexed for MEDLINE]

5:

Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening.

LaDisa JF Jr, Olson LE, Hettrick DA, Warltier DC, Kersten JR, Pagel PS.

Biomed Eng Online. 2005 Oct 26;4:59.

PMID: 16250918 [PubMed - indexed for MEDLINE]

6:

Numerical investigation of blood flow in a sequential aorto-coronary bypass graft model.

S M, Ghista DN, Chua LP, Seng TY.

Conf Proc IEEE Eng Med Biol Soc. 2006;1:875-8.

PMID: 17945605 [PubMed - indexed for MEDLINE]

7:

Effect of mechanical aortic valve orientation on coronary artery flow: comparison of tilting disc versus bileaflet prostheses in pigs.

Kleine P, Scherer M, Abdel-Rahman U, Klesius AA, Ackermann H, Moritz A.

J Thorac Cardiovasc Surg. 2002 Nov;124(5):925-32.

PMID: 12407375 [PubMed - indexed for MEDLINE]

8:

Combined effects of pulsatile flow and dynamic curvature on wall shear stress in a coronary artery bifurcation model.

Pivkin IV, Richardson PD, Laidlaw DH, Karniadakis GE.

J Biomech. 2005 Jun;38(6):1283-90.

PMID: 15863113 [PubMed - indexed for MEDLINE]

9:

Three-dimensional computational fluid dynamics modeling of alterations in coronary wall shear stress produced by stent implantation.

LaDisa JF Jr, Guler I, Olson LE, Hettrick DA, Kersten JR, Warltier DC, Pagel PS.

Ann Biomed Eng. 2003 Sep;31(8):972-80.

PMID: 12918912 [PubMed - indexed for MEDLINE]

10:

Simulation of arterial hemodynamics after partial prosthetic replacement of the aorta.

Bauernschmitt R, Schulz S, Schwarzhaupt A, Kiencke U, Vahl CF, Lange R, Hagl S.

Ann Thorac Surg. 1999 Mar;67(3):676-82.

PMID: 10215210 [PubMed - indexed for MEDLINE]

11:

Coronary flow characteristics after a Bentall procedure with or without sinuses of Valsalva.

de Paulis R, Tomai F, Bertoldo F, Ghini AS, Scaffa R, Nardi P, Chiariello L.

Eur J Cardiothorac Surg. 2004 Jul;26(1):66-72.

PMID: 15200981 [PubMed - indexed for MEDLINE]

12:

Predictive haemodynamics in a one-dimensional human carotid artery bifurcation. Part II: Application to graft design.

Kolachalama VB, Bressloff NW, Nair PB, Shearman CP.

IEEE Trans Biomed Eng. 2008 Mar;55(3):1176-84.

PMID: 18334411 [PubMed - indexed for MEDLINE]

13:

Computational simulation of intracoronary flow based on real coronary geometry.

Boutsianis E, Dave H, Frauenfelder T, Poulikakos D, Wildermuth S, Turina M, Ventikos Y, Zund G.

Eur J Cardiothorac Surg. 2004 Aug;26(2):248-56.

PMID: 15296879 [PubMed - indexed for MEDLINE]

14:

The effect of angle on wall shear stresses in a LIMA to LAD anastomosis: numerical modelling of pulsatile flow.

Freshwater IJ, Morsi YS, Lai T.

Proc Inst Mech Eng [H]. 2006 Oct;220(7):743-57.

PMID: 17117764 [PubMed - indexed for MEDLINE]

15:

Modeling of antegrade and retrograde flow into a branch artery of the aorta: implications for endovascular stent-grafting and extra-anatomical visceral bypass.

Sutalo ID, Lawrence-Brown MM, Ahmed S, Liffman K, Semmens JB.

J Endovasc Ther. 2008 Jun;15(3):300-9.

PMID: 18540695 [PubMed - indexed for MEDLINE]

16:

Aortic root dynamics are asymmetric.

Lansac E, Lim HS, Shomura Y, Lim KH, Rice NT, Goetz WA, Duran CM.

J Heart Valve Dis. 2005 May;14(3):400-7.

PMID: 15974536 [PubMed - indexed for MEDLINE]

17:

Flow dynamics of the St Jude Medical Symmetry aortic connector vein graft anastomosis do not contribute to the risk of acute thrombosis.

Redaelli A, Maisano F, Ligorio G, Cattaneo E, Montevecchi FM, Alfieri O.

J Thorac Cardiovasc Surg. 2004 Jul;128(1):117-23.

PMID: 15224030 [PubMed - indexed for MEDLINE]

18:

Numerical model study of flow dynamics through an end-to-side anastomosis: choice of anastomosis angle and prosthesis diameter.

Pousset Y, Lermusiaux P, Berton G, Le Gouez JM, Leroy R.

Ann Vasc Surg. 2006 Nov;20(6):773-9.

PMID: 17136315 [PubMed - indexed for MEDLINE]

19:

Fundamental mechanics of aortic heart valve closure.

Hose DR, Narracott AJ, Penrose JM, Baguley D, Jones IP, Lawford PV.

J Biomech. 2006;39(5):958-67.

PMID: 16488234 [PubMed - indexed for MEDLINE]

20:

Time-dependent 3D simulations of the hemodynamics in a stented coronary artery.

Faik I, Mongrain R, Leask RL, Rodes-Cabau J, Larose E, Bertrand O.

Biomed Mater. 2007 Mar;2(1):S28-37. Epub 2007 Mar 2.

PMID: 18458417 [PubMed - indexed for MEDLINE]

Items 1 - 20 of 114
of 6Next