Your browser version may not work well with NCBI's Web applications. More information here...
Related Articles, Links

ECG beat detection using filter banks.

Afonso VX, Tompkins WJ, Nguyen TQ, Luo S.

Endocardial Solutions, Inc., Saint Paul, MN 55108, USA.

We have designed a multirate digital signal processing algorithm to detect heart beats in the electrocardiogram (ECG). The algorithm incorporates a filter bank (FB) which decomposes the ECG into subbands with uniform frequency bandwidths. The FB-based algorithm enables independent time and frequency analysis to be performed on a signal. Features computed from a set of the subbands and a heuristic detection strategy are used to fuse decisions from multiple one-channel beat detection algorithms. The overall beat detection algorithm has a sensitivity of 99.59% and a positive predictivity of 99.56% against the MIT/BIH database. Furthermore this is a real-time algorithm since its beat detection latency is minimal. The FB-based beat detection algorithm also inherently lends itself to a computationally efficient structure since the detection logic operates at the subband rate. The FB-based structure is potentially useful for performing multiple ECG processing tasks using one set of preprocessing filters.

Publication Types:
PMID: 9932341 [PubMed - indexed for MEDLINE]