Table 3

Energy flows in torso skin compartment after 45 minutes of RF exposure at 2450 MHz (350 W/m2). All energy flows expressed in watts. Positive numbers correspond to power deposited into skin compartment.


24°C
28°C
31°C


RF Exposure
No RF
difference
RF Exposure
No RF
Difference
RF Exposure
No RF
difference

RF power into torso skin compartment
38.1

38.1
38.1

38.1
38.1

38.1
Metabolic heating in skin
0.5
0.5
0.0
0.5
0.5
0.0
0.5
0.5
0.0
Conducted into skin from fat
20.7
37.6
-16.9
9.1
25.7
-16.6
9.8
15.9
-6.2
Evaporative heat loss from skin
-3.7
-3.8
0.0
-4.2
-3.8
0.0
-22.5
-7.6
-14.9
Power loss by radiation and convective cooling
-55.5
-36.1
-19.4
-43.3
-24.9
-18.4
-30.6
-18.4
-12.2
Heat added to skin by blood flow
1.7
1.8
-0.1
3.2
2.5
0.7
4.9
9.6
-4.7
Net power into skin compartment*
1.8
0.0
1.7
3.4
0.0
3.8
0.2
0.0
0.1

*Net of power flows. Numbers may not sum to zero because of heat storage in skin and rounding errors

Foster and Adair BioMedical Engineering OnLine 2004 3:4   doi:10.1186/1475-925X-3-4